可降解纯铁薄膜的制备和血液相容性 |
朱生发;徐莉;李贵才;石志峰;孙鸿;黄楠 |
西南交通大学材料先进技术教育部重点实验室;中国工程物理研究院 |
|
The preparation and blood compatibility of pure iron thin film using filter cathode vacuum arc |
Sheng-Fa ZHU;;;;; |
西南交通大学材料先进技术教育部重点实验室;中国工程物理研究院 |
引用本文:
朱生发; 徐莉; 李贵才; 石志峰; 孙鸿; 黄楠 . 可降解纯铁薄膜的制备和血液相容性[J]. 材料研究学报, 2008, 22(5): 495-499.
,
,
,
,
,
.
The preparation and blood compatibility of pure iron thin film using filter cathode vacuum arc[J]. Chin J Mater Res, 2008, 22(5): 495-499.
1 U.Sigwart,J.Puel,V.Mirkovitch,F.Joffre, L.Kappenberger,Intracoronary stents to prevent oc- clusion and restenosis after transluminal angioplasty,The New England Journal of Medicine,316,701(1987) 2 C.D.Mario,H.Griffiths,O.Goktekin,N.Peeters,J.Verbist, M.Bosiers,K.Deloose,B.Heublein,R.Rohde,V.Kasese, C.Ilsley,R.Erbel,Drug-eluting bioabsorbable magnesium stent,J.Interv.Cardio,17(6),391(2004) 3 B.Heublein,R.Rohde,V.Kaese,M.Niemeyer,W.Hartung, A.Haverich,Biocorrosion of magnesium alloys:a new principle in cardiovascular implant technology? Heart,89, 651(2003) 4 R.Waksman,Metallic bioabsorbable stents:concepts,ex- perimental findings,early clinical results and the future, ACC Current Journal Review,14(10),36(2005) 5 G.Mani,M.D.Feldman,Coronary stents:A materials per- spective,Biomaterials,28,1689(2007) 6 M.Peuster,P.Wohlsein,M.Brügmann,M.Ehlerding, K.Seidler,C.Fink,H.Brauer,A.Fischer,G.Hausdorf,A novel approach to temporary stenting:degradable car- diovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits,Heart,86(5),563(2001) 7 M.Peuster,C.Hesse,T.Schloo,T.Schloo,C.Fink, P.Beerbaum,C.von Schnakenburg,Long-term biocompat- ibility of a corrodible peripheral iron stent in the porcine descending aorta,Biomaterials,27,4955(2006) 8 P.P.Mueller,T.Maya,A.Perz,H.Hauser,M.Peuster,Con- trol of smooth muscle cell proliferation by ferrous iron. Biomaterials,27(10),2193(2006) 9 N.Huang,P.Yang,Y.X.Leng,J.Y.Chen,H.Sun,J.Wang, G.J.Wang,P.D.Ding,T.F.Xi,Y.Leng,Hemocompatibility of titanium oxide films,Biomaterials,24,2177(2003) 10 N.Huang,P.Yang,Y.X.Leng,J.Wang,H.Sun,J.Y.Chen, G.J.Wan,Surface modification of biomaterials by plasma immersion ion implantation,Surf.Coat.Technol.,186, 218(2004) 11 M.I.Jones,I.R.McColl,D.M.Grant,K.G.Parker, T.L.Parker,Protein adsorption and platelet attach- ment and activation,on TiN,TiC,and DLC coatings on titanium for cardiovascular applications,J.Biomed Mater.Res.,52,413(2000) 12 Y.X.Leng,H.Sun,P.Yang,J.Y.Chen,J.Wang,G.J.Wan, N.Huang,X.B.Tian,Biomedical properties of tantalum ni- tride films synthesized by reactive magnetron sputtering, Thin Solid Films,398/399,471(2001) 13 F.Z.Cui,D.J.Li,A review of investigations on biocompat- ibility of diamond-like carbon and carbon nitride films, Surf.Coat.Technol.,131,481(2000) 14 ZHANG Xiyan,LI Cong,SHI Minghua,LIU Nianfu,QIU Shaoyu,ZHANG Qiang,The relation between grain size and the corrosion resistance of nanocrystalline zircaloy-4, Rare Metal Materials and Engineering,37(2),273(2008) (张喜燕,李聪,石明华,刘年富,邱绍宇,张强,纳米结构锆-4合金腐蚀速率与晶粒尺寸的关系,稀有金属材料与工程,37(2),273(2008)) |
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
|
Shared |
|
|
|
|
|
Discussed |
|
|
|
|