Abstract Shot--peening and ion implantation were adopted to treat the surface of the
machined specimens of Ti--6--22--22 alloy, and the stress controlled fatigue
tests were performed at room temperature and 400℃, respectively. Experimental
results indicated that the effect of shot--peening and ion implantation on
the $S$--$N$ curves is related to temperature. Both shot--peening and ion--implantation
have little effect on the fatigue strength at room temperature, but substantially
increase the fatigue strength at 400℃ comparing with the untreated counterparts.
SEM fractography surface analysis indicates that fatigue cracks of the
treated samples initiate at ~subsurface after long--time fatigue at 400℃
|
Received: 04 November 2004
|
|
1 X.D.Zhang, J.M.K.Wiezorek, W.A.Baeslack, D.J.Evans, H.L.Fraser, Acta Metall, 46, 85(1998) 2 T.Drr, L.Wagner, In: Proceedings of the Sixth International Conference on Shot Peening, Jack Champaigne eds., 223(1996) 3 Korzynski Mieczyslaw, In: Proceedings of the Sixth International Conference on Shot Peening, Jack Champaigne eds., 282(1996) 4 A.Drechsler, T.Dorr, L.Wagner, Mat. Sci. Eng., A243(1~2) , 217(1998) 5 L.Wagner, Mat. Sci. Eng., A263, 210(1999) 6 C.J.Mchargue, Int. Mater. Rev., 31(2) , 49(1986) 7 K.V.Jata, E.A.Starke, JOM-J. MIN. MET. MAT, S, 35(8) , 23(1983) 8 R.G.Vardiman, R.A.Kant, J. Appl. Phys., 53(1) , 690(1982) 9 R.Hutchings, Mater. Sci. Eng., A69, 129(1985) 10 B.R.Sridhar, K.Ramachandra, K.A.Padmanabhan, J. Mater. Sci., 31(16) , 4381(1996) 11 S.C.Tjong, S.M.Zhu, Scr. Mater., 32, 535(1995) |