表2 P110钢在不同时间添加复配杀菌剂后腐蚀14 d后的Tafel曲线拟合结果
Table 2 Tafel curves fitting results of P110 steel after corrosion for 14 d with addition of compounded biocides at different time
With/without compounded biocidesba / mVbc / mVEcorr / mVIcorr / A·cm-2
No compounded biocides50.45694.1-58626.4 × 10-5
Addition of compounded biocides after 0 d102.2226.9-7013.58 × 10-5
Addition of compounded biocides after 3 d57.27109.7-6420.52 × 10-5
Addition of compounded biocides after 7 d329.480.80-7632.51 × 10-5
Addition of compounded biocides after 14 d83.95449.7-55014.0 × 10-5