复配杀菌缓蚀剂对N80钢在SRB环境中微生物腐蚀行为的影响
|
胥聪敏, 李雪丽, 付安庆, 孙姝雯, 陈志强, 李城臣
|
Effect of Compound Bactericidal Corrosion Inhibitor on Corrosion Behavior of N80 Steel at Different Temperatures
|
XU Congmin, LI Xueli, FU Anqing, SUN Shuwen, CHEN Zhiqiang, LI Chengchen
|
|
表3 N80在不同温度SRB溶液中腐蚀14 d的EIS拟合结果
|
Table 3 EIS fitting results of 14 d corrosion of N80 in SRB solution at different temperatures
|
|
Temperature | Rs | Yf | nf | Rf | Ydl | ndl | Rct | W | Equivalent circuit |
---|
Without adding compound bactericidal corrosion inhibitor | 20 oC | 16.24 | 6.14 × 10-3 | 1.00 | 42.19 | 7.716 × 10-2 | 0.977 | 756.3 | - | Fig.4a | 37 oC | 16.36 | 9.30 × 10-2 | 0.95 | 361.9 | 1.054 × 10-2 | 0.69 | 9.43 | - | Fig.4a | 50 oC | 10.08 | 5.16 × 10-4 | 1.00 | 447.9 | 4.689 × 10-4 | 1.00 | 307.4 | - | Fig.4a | Adding compound bactericidal corrosion inhibitor | 20 oC | 19.81 | 2.98 × 10-3 | 1.00 | 192.3 | 1.256 × 10-3 | 0.87 | 2960 | - | Fig.4a | 37 oC | 19.76 | 1.69 × 10-3 | 1.00 | 9937 | 2.50 × 10-3 | 0.86 | 10.11 | - | Fig.4a | 50 oC | 19.13 | 6.42 × 10-4 | 0.91 | 482.2 | 1.747 × 10-3 | 0.88 | 50.36 | 3.75 × 10-3 | Fig.4b |
|
|
|