扫描电化学显微镜原位观察碳钢涂层缺陷处的交流腐蚀行为
公维炜, 杨丙坤, 陈云, 郝文魁, 王晓芳, 陈浩

In Situ SECM Observation of Corrosion Behavior of Carbon Steel at Defects of Epoxy Coating under AC Current Conditions
GONG Weiwei, YANG Bingkun, CHEN Yun, HAO Wenkui, WANG Xiaofang, CHEN Hao
表2 各等效电路元件拟合结果
Table 2 Fitted values of the elements of the equivalent circuit
AC current densityImmersion time

Cf

/μF·cm-2

Qd

Rf

/Ω·cm2

Rp

/Ω·cm2

Cd

/μF·cm-2

n
50 A/m20 h2.71×10-36.660.79164.38.95×104
5 h7.87×10-355.50.75116.96.17×104
10 h8.59×10-331.50.9545.9420.55
24 h3.72×10-3103.10.70119.35.06×104
100 A/m20 h2.71×10-36.660.79164.38.95×104
5 h3.90×10-38.090.80136.54.95×104
10 h1.12×10-22730.7036.551.51×104
24 h1.18×10-246.60.78114.65.65×104
300 A/m20 h8.33×10-39.650.77138.96.77×104
5 h1.49×10-294.90.7468.733.09×104
10 h15.968.40.6667.691.30×104
24 h9.06×10-371.80.75252.83.34×104