在盐湖地区暴露48个月纯锌的腐蚀行为
|
张丹,王振尧
|
Corrosion Behavior of Zinc Exposed to Salt Lake Area for 48 Months
|
Dan ZHANG,Zhenyao WANG
|
|
表2 拟合所得锌的电化学阻抗谱参数 |
Table 2 Fitted EIS parameters of zinc |
|
Corrosion | The skyward one | The field-ward one |
---|
time/month | 6 | 12 | 24 | 48 | 6 | 12 | 24 | 48 | Rs/Ω·cm2 | 17.18 | 2.75 | 21.28 | 34.28 | 16.52 | 30.84 | 32.11 | 28.24 | Q1/(Ω·cm2·Sn)-1 | 3.444×10-5 | 1.052×10-4 | 1.929×10-4 | 3.743×10-5 | 9.311×10-5 | 7.300×10-5 | 8.348×10-5 | 1.497×10-4 | n1 | 0.557 | 0.351 | 0.444 | 0.495 | 0.425 | 0.502 | 0.552 | 0.453 | Rr/Ω·cm2 | 317 | 1099 | 1044 | 608.6 | 541 | 708.2 | 1592 | 2379 | Q2/(Ω·cm2·Sn)-1 | 8.283×10-4 | 1.163×10-3 | 2.095×10-2 | 0.193 | 6.685×10-4 | 3.72×10-3 | 1.6810-2 | 1.806×10-2 | n2 | 0.484 | 0.637 | 0.779 | 0.609 | 0.662 | 0.471 | 0.869 | 0.926 | Rt/Ω·cm2 | 786.3 | 572.3 | 320.1 | 432 | 549.8 | 761.4 | 620 | 431.8 |
|
|
|